MIL-PRF-44059E
area shall be such that the distributed product does not completely cover all the openings of the
sieve. The sieve shall be tilted at approximately a 450 angle and allowed to drain for 2 minutes
before determining the drained weight by subtracting the sieve tare weight from the gross weight.
The drained weight shall be reported to the nearest 0.1 ounce.
4.5.7 Palatability. Palatability acceptability is determined by compliance with 4.4.
4.5.8 Nutrient content. The sample to be analyzed shall be a composite of eight filled and
sealed pouches which have been selected at random from the lot. The composite sample shall be
prepared and analyzed for water content, protein content, fat content, ash content, and salt
content in accordance with the following methods of the Official Methods of Analysis of AOAC
International:
Method Number
Test
Moisture
950.46A
Protein
988.05
Fat
960.39
Ash
923.03
Salt
935.47
Test results shall be reported to the nearest 0.1 percent. Any result not conforming to the
requirements specified in 3.2.8 shall be cause for rejection of the lot.
5. PACKAGING
5.1 Packaging. Packaging shall be as specified in MIL-PRF-44073.
6. NOTES
(This section contains information of a general or explanatory nature that maybe helpful, but
is not mandatory.)
6.1 Acquisition requirements. Acquisition documents must specify the following:
a. Title, number, and date of the specification.
b. Issue of DoDISS to be cited in the solicitation, and if required, the specific issue of
individual documents referenced (see 2.2.1 and 2.3).
c. When a first article is not required (see 3.1 ).
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business